If you experience issues with multiple channel (switch) status when using Shelly Wave (Shelly Wave 2PM for example) within Fibaro HC3 please refer to below:

The issue you're experiencing is caused by the gateway (HC3) incorrectly setting the lifeline. Fibaro gateways automatically assign the lifeline to a single channel, even for multi-channel devices. As a result, the reports triggered by the switch are sent to the root device instead of the appropriate endpoints.

To resolve this, please adjust the device's settings by assigning the multi-channel lifeline instead of the single channel one in the association settings. Please refer to below image showing this process

 

HC3 Setting Multi Channel Lifeline

https://support.shelly.cloud/en/support/solutions/articles/103000301304-hc3-setting-mc-multi-channel-association