Skip to content
  • There are no suggestions because the search field is empty.

Algo 8312 Troubleshooting

Scenario: Customer reporting they had an Algo 8312. When a call is placed to the PA system, the announcement call remains active for a maximum of approximately 30 seconds, after which the call is automatically disconnected.

Issue 2: Unable to Make Consecutive Announcements Immediately

After completing the first announcement, users must wait approximately 30 seconds before they can successfully place another call to the PA system. Any attempt to make a subsequent announcement immediately after the first one results in the call not connecting until the waiting period has elapsed.

 

Feedback from Algo:

Ensure the Algo devices are running on the latest firmware - Click Here

The only setting on Algo devices that could cause the page announcement to be cut short is Page Timeout, located under Basic Settings -> Features.

As for subsequent calls failing, there’s nothing on teh Algo end that would control that either. The only situation where the device would refuse a call is when it is already busy with an announcement of the same or higher priority. This is likely a network-level or phone system-level issue. Algo's general recommendation is to disable SIP ALG on the network, as it tends to cause more problems than it solves. Ultimately, it would be ideal to obtain the 8312 log file and configuration file from the affected site. The log should be extracted after the issue has been reproduced (calls being cut short at 30 seconds and subsequent call failures), but before rebooting the device. System Log: Export from System -> System Log.Configuration File: Export from System -> Maintenance.

 

Customer Response:

 As we didn't have access to the network configuration we changed the below settings on the Algo and helped with the delay after hangup and static noise:

Changed "SIP Transportation" from Auto to TCP.

Lowered the Register Period (seconds) from 3600 to 120. 

image-Oct-29-2026-03-08-15-9094-AM